Biodolomer® E 900328

Biodolomer® E 900328

Biodolomer® E 900328 is a biomaterial developed
for the extrusion of thin tube, pipe and straws.

It is basically a compound of a biodegradable aliphatic aromatic copolyester (PBAT), PLA, and minerals.

Property

Unit

Test method

Grade 900328

Mass Density

g/cm3

ISO 1183

1.28

Bulk Density

kg/m3

DIN EN ISO 60

800

MFI 190°C, 2.16 kg

g/1 min

ISO 1133

3.5

Melting Temp

°C

DSC

155

Heat Distortion Temperature B (0.45MPa)

°C

DSC

68

Transmission

Opaque

Tensile Strength

MPa

ISO 527

26

E-modulus

MPa

ISO 527

176

Elongation

%

ISO 527

59

Shore Hardness

D

ISO 868

70

Industrial Composting

Microns

DIN CERTCO

1000

Industrial Composting

Microns

BPI

1000

Food Contact

-

Eurofins

Yes

Food Contact

-

FDA

Possible

Animal-Derived Content

-

-

No

Typical Basic Material properties of grade 900328

Certification of Compostability and Biodegrade

Biodolomer® E fulfills the requirements of the existing standards for compostable and biodegradable polymers because it can be degraded by microorganisms.


The biodegradation process in soil depends on the specific environment (climate, soil quality, population of microorganisms).

Food Regulatory Status

Biodolomer® E is one of the few compostable polymers, that complies in its composition with the European foodstuff legislation for food contact, EU Directive 10 / 2011 / EC with amendment 2023/1442.


Specific limitations and more details are given on request. The converter or packer has to check the suitability of the article for the application.

Biodolomer® E 900328

Form supplied and Storage

Biodolomer® E is supplied as lenticular pellets in 1 t big bags. any time. Storage time of unopened bags is at least 12 months at room temperature (23 °C).

Applications

Biodolomer® E has been developed for the conversion to extruded thin tubes. Typical applications are straws for drinks & beverages.


In view of numerous factors influencing the functionality and shelf life of Biodolomer® E finished articles the production parameters have to be tested by the converters before utilization.

Note

The information submitted in this document is based on our current knowledge and experience. In view of the many factors that may affect processing and application, these data do not relieve processors of the responsibility of carrying out their own tests and experiments; neither do they imply any legally binding assurance for a special purpose. It is the responsibility of those to whom we supply our products to ensure that any proprietary rights and existing laws and legislation are observed.

Datasheet updated

2025-08-05 9:30

(supersedes all previous editions)

bottom of page